TY - JOUR
T1 - Split aptamer acquisition mechanisms and current application in antibiotics detection
T2 - a short review
AU - Ye, Hua
AU - Yang, Zhixin
AU - Khan, Imran Mahmood
AU - Niazi, Sobia
AU - Guo, Yuanxin
AU - Wang, Zhouping
AU - Yang, Hongshun
N1 - Publisher Copyright:
© 2022 Taylor & Francis Group, LLC.
PY - 2023
Y1 - 2023
N2 - Antibiotic contamination is becoming a prominent global issue. Therefore, sensitive, specific and simple technology is desirable the demand for antibiotics detection. Biosensors based on split aptamer has gradually attracted extensive attention for antibiotic detection due to its higher sensitivity, lower cost, false positive/negative avoidance and flexibility in sensor design. Although many of the reported split aptamers are antibiotics aptamers, the acquisition and mechanism of splitting is still unknow. In this review, six reported split aptamers in antibiotics are outlined, including Enrofloxacin, Kanamycin, Tetracycline, Tobramycin, Neomycin, Streptomycin, which have contributed to promote interest, awareness and thoughts into this emerging research field. The study introduced the pros and cons of split aptamers, summarized the assembly principle of split aptamer and discussed the intermolecular binding of antibiotic-aptamer complexes. In addition, the recent application of split aptamers in antibiotic detection are introduced. Split aptamers have a promising future in the design and development of biosensors for antibiotic detection in food and other field. The development of the antibiotic split aptamer meets many challenges including mechanism discovery, stability improvement and new biosensor development. It is believed that split aptamer could be a powerful molecular probe and plays an important role in aptamer biosensor.
AB - Antibiotic contamination is becoming a prominent global issue. Therefore, sensitive, specific and simple technology is desirable the demand for antibiotics detection. Biosensors based on split aptamer has gradually attracted extensive attention for antibiotic detection due to its higher sensitivity, lower cost, false positive/negative avoidance and flexibility in sensor design. Although many of the reported split aptamers are antibiotics aptamers, the acquisition and mechanism of splitting is still unknow. In this review, six reported split aptamers in antibiotics are outlined, including Enrofloxacin, Kanamycin, Tetracycline, Tobramycin, Neomycin, Streptomycin, which have contributed to promote interest, awareness and thoughts into this emerging research field. The study introduced the pros and cons of split aptamers, summarized the assembly principle of split aptamer and discussed the intermolecular binding of antibiotic-aptamer complexes. In addition, the recent application of split aptamers in antibiotic detection are introduced. Split aptamers have a promising future in the design and development of biosensors for antibiotic detection in food and other field. The development of the antibiotic split aptamer meets many challenges including mechanism discovery, stability improvement and new biosensor development. It is believed that split aptamer could be a powerful molecular probe and plays an important role in aptamer biosensor.
KW - Antibiotics
KW - biosensor
KW - detection
KW - mechanisms
KW - split aptamer
UR - http://www.scopus.com/inward/record.url?scp=85129397764&partnerID=8YFLogxK
U2 - 10.1080/10408398.2022.2064810
DO - 10.1080/10408398.2022.2064810
M3 - Review article
C2 - 35507474
AN - SCOPUS:85129397764
SN - 1040-8398
VL - 63
SP - 9098
EP - 9110
JO - Critical Reviews in Food Science and Nutrition
JF - Critical Reviews in Food Science and Nutrition
IS - 28
ER -