TY - JOUR
T1 - Investigation on combined effect of humidity–temperature on partial discharge through dielectric performance evaluation
AU - Ji, Yatai
AU - Giangrande, Paolo
AU - Zhao, Weiduo
AU - Madonna, Vincenzo
AU - Zhang, He
AU - Li, Jing
AU - Galea, Michael
N1 - Publisher Copyright:
© 2022 The Authors. IET Science, Measurement & Technology published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology.
PY - 2022/9/30
Y1 - 2022/9/30
N2 - The humidity role in the partial discharge (PD) inception mechanism is quite challenging, especially when considering the environmental temperature. Indeed, there is no general rule to explain the humidity effect on the PD phenomenon. In this paper, the PD activity in inter-turn insulation is experimentally investigated for different relative humidity (RH) conditions at three different ambient temperatures, that is, 30°C, 60°C, and 90°C. Partial discharge inception voltage (PDIV) is directly measured through a photomultiplier tube (PMT), whereas the tip-up tests are performed aiming at monitoring both dissipation factor (tanδ) and insulation capacitance (IC). These extra measurements (diagnostic dielectric markers) allow better assessing the insulation status. The adoption of the tip-up test enables the insulation properties measurement. Based on the tip-up tests’ findings, the interfacial polarization process starts at 75% RH under 60°C, while the high conductivity area is already formed at 75% RH when the ambient temperature is 90°C. The water film formation deduced from the tip-up test is then used to explain the trend of PDIV, and the validity is further proved by finite element analysis (FEA).
AB - The humidity role in the partial discharge (PD) inception mechanism is quite challenging, especially when considering the environmental temperature. Indeed, there is no general rule to explain the humidity effect on the PD phenomenon. In this paper, the PD activity in inter-turn insulation is experimentally investigated for different relative humidity (RH) conditions at three different ambient temperatures, that is, 30°C, 60°C, and 90°C. Partial discharge inception voltage (PDIV) is directly measured through a photomultiplier tube (PMT), whereas the tip-up tests are performed aiming at monitoring both dissipation factor (tanδ) and insulation capacitance (IC). These extra measurements (diagnostic dielectric markers) allow better assessing the insulation status. The adoption of the tip-up test enables the insulation properties measurement. Based on the tip-up tests’ findings, the interfacial polarization process starts at 75% RH under 60°C, while the high conductivity area is already formed at 75% RH when the ambient temperature is 90°C. The water film formation deduced from the tip-up test is then used to explain the trend of PDIV, and the validity is further proved by finite element analysis (FEA).
UR - http://www.scopus.com/inward/record.url?scp=85139058541&partnerID=8YFLogxK
U2 - 10.1049/smt2.12128
DO - 10.1049/smt2.12128
M3 - Article
AN - SCOPUS:85139058541
SN - 1751-8822
VL - 17
SP - 37
EP - 46
JO - IET Science, Measurement and Technology
JF - IET Science, Measurement and Technology
IS - 1
ER -