TY - JOUR
T1 - Improving peptide relative quantification in MALDI-TOF MS for biomarker assessment
AU - Albalat, Amaya
AU - Stalmach, Angelique
AU - Bitsika, Vasiliki
AU - Siwy, Justyna
AU - Schanstra, Joost P.
AU - Petropoulos, Alexandros D.
AU - Vlahou, Antonia
AU - Jankowski, Joachim
AU - Persson, Frederik
AU - Rossing, Peter
AU - Jaskolla, Thorsten W.
AU - Mischak, Harald
AU - Husi, Holger
PY - 2013/10
Y1 - 2013/10
N2 - Proteomic profiling by MALDI-TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI-TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI-TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI-TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).
AB - Proteomic profiling by MALDI-TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI-TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI-TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI-TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).
KW - Biomarker
KW - MALDI-TOF MS
KW - Proteomic profiling
KW - Relative quantification
KW - Technology
KW - Urine
UR - http://www.scopus.com/inward/record.url?scp=84885417510&partnerID=8YFLogxK
U2 - 10.1002/pmic.201300100
DO - 10.1002/pmic.201300100
M3 - Article
C2 - 23943474
AN - SCOPUS:84885417510
SN - 1615-9853
VL - 13
SP - 2967
EP - 2975
JO - Proteomics
JF - Proteomics
IS - 20
ER -