@inproceedings{484093feda494a4dbe6e1c7070b948ba,
title = "Analysis of Energy Storage System Requirements for Aircraft Electric Taxiing Operations",
abstract = "This paper focuses on evaluating the energy and power requirements of a specific aircraft on-board electric taxiing (ET) system. The developed model of the investigated system is used to determine the requisites for a typical taxiing profile mission of a Boeing 737-400. Besides the derivation of the specifications, the comparison of batteries and electrochemical capacitors is outlined in the light of viable candidates for a local energy storage system (LESS). It is estimated that LESS should be sized for capacity of 19kWh and peak power of 81kW. The paper is concluded with a comparison and discussion on LESS topologies.",
keywords = "Batteries, Electric taxiing, Energy Storage, Modelling, Supercapacitors",
author = "Milos Lukic and Paolo Giangrande and Christian Klumpner and Michael Galea",
note = "Publisher Copyright: {\textcopyright} 2019 IEEE.; 45th Annual Conference of the IEEE Industrial Electronics Society, IECON 2019 ; Conference date: 14-10-2019 Through 17-10-2019",
year = "2019",
month = oct,
doi = "10.1109/IECON.2019.8926797",
language = "English",
series = "IECON Proceedings (Industrial Electronics Conference)",
publisher = "IEEE Computer Society",
pages = "2616--2621",
booktitle = "Proceedings",
address = "United States",
}