Skip to main navigation Skip to search Skip to main content

Multicenter analysis of nuclear cataract population parameters and their clinical correlations based on AS-OCT

  • Ziying Liu*
  • , Lingxi Hu
  • , Tianhang Liu*
  • , Zunjie Xiao
  • , Yinglin Zhang
  • , Risa Higashita
  • , Chen Lin
  • , Sunee Chansangpetch
  • , Jiang Liu*
  • *Corresponding author for this work

Research output: Journal PublicationArticlepeer-review

Abstract

To investigate the extent of lens opacity image features measured by AS-OCT and their association with disease severity based on Lens Opacities Classification System III (LOCS III) in eyes with nuclear cataract (NC) and to determine the diagnostic performance of relative features for grading of nuclear lens opacity.Setting: – Multicenter study at 2 sites.Design: – Clinical validation.Methods: – A total of 127 individuals with different severity of nuclear cataract were recruited from two different clinical centers: Thailand (Thai, n=81) and Shenzhen, China (SZRM, n=46). All patients underwent AS-OCT examination, images were graded under the LOCS III standard. Automated machine learning models were developed to extract the nuclear region annotation, feature-based quantifiers were then analyzed and evaluated through classifying cataract severity based on disease severity according to LOCS III.Results: – AS-OCT pixel based features such as mean, variance, Root Mean Square (RMS), interquartile range, and percentiles significantly correlate with nuclear cataract grading (p < 0.01). Features such as variance, standard deviation, and median showed high consistency, while kurtosis and skewness were negatively correlated. Prediction model achieved 0.81 accuracy on SZRM center (F1-score 0.82), and 0.87 accuracy on Thai center (F1-score 0.83).Conclusions: – Automated AS-OCT image features has strong consistency in lens opacity grading. Potentials are also shown in supportive diagnosis and surgical planning in nuclear cataract.

Original languageEnglish
JournalJournal of Cataract and Refractive Surgery
DOIs
Publication statusAccepted/In press - 2026

Free Keywords

  • AI-assisted annotation
  • AS-OCT
  • Multi-regional quantification
  • Nuclear cataract

ASJC Scopus subject areas

  • Surgery
  • Ophthalmology
  • Sensory Systems

Fingerprint

Dive into the research topics of 'Multicenter analysis of nuclear cataract population parameters and their clinical correlations based on AS-OCT'. Together they form a unique fingerprint.

Cite this