Skip to main navigation Skip to search Skip to main content

Generative Artificial Intelligence for Postoperative Parameters Prediction in Implantable Collamer Lens Surgery

  • Yinglin Zhang
  • , Ruiling Xi
  • , Lingxi Zeng
  • , Risa Higashita*
  • , Keiichiro Okamoto
  • , Tomoaki Nakamura
  • , Akihito Igarashi
  • , Seiichiro Hata
  • , Kazunori Miyata
  • , Kazutaka Kamiya*
  • , Jiang Liu*
  • *Corresponding author for this work

Research output: Journal PublicationArticlepeer-review

1 Citation (Scopus)

Abstract

Purpose: – To predict multiple postoperative parameters following implantable collamer lens (ICL) surgery with generative artificial intelligence, using preoperative anterior segment optical coherence tomography (AS-OCT) images as the input.Setting: – Daikanyama Eye Clinic, Tokyo, Japan; Miyata Eye Hospital, Miyazaki, Japan; Nagoya Eye Clinic, Nagoya, Japan; Yokohama Sky Eye Clinic, Kanagawa, Japan.Design: – Retrospective Study.METHODS: – Our research involved paired preoperative and postoperative AS-OCT images from 1010 patients (1585 eyes) who underwent horizontal ICL implantation, and 86 patients (86 eyes) who received vertical implantation from four clinical centers. A Generative Adversarial Network, ICL-GAN, was employed to predict postoperative structures based on preoperative AS-OCT slice from each eye. Postoperative parameters, including vault, AOD500, and TIA500, were measured from the predicted postoperative structures. The prediction error was evaluated using the mean absolute error (MAE) and root mean square error (RMSE). The correlation and agreement between the prediction and the achieved values were also analyzed.RESULTS: – The vaults measured from the predictions of postoperative anatomical structure have a strong correlation with the achieved values on horizontal data (r=0.659, p<0.01 for ICL size of 12.1mm, r=0.799, p<0.01 for 12.6mm, and r=0.737, p<0.01 for 13.2mm) and when compared with the NK-formula and KS-formula achieved the minimum prediction errors (MAE are 105 μm, 114 μm, and 111 μm). ICL-GAN also performed best on the vertical implantation data. The AOD500 and TIA500 also showed good correlation and agreement with the achieved values.CONCLUSION: – The generative artificial intelligence demonstrates the capability to predict multiple postoperative parameters following ICL surgery.

Original languageEnglish
JournalJournal of Cataract and Refractive Surgery
VolumePublish Ahead of Print
DOIs
Publication statusPublished - 2026

ASJC Scopus subject areas

  • Surgery
  • Ophthalmology
  • Sensory Systems

Fingerprint

Dive into the research topics of 'Generative Artificial Intelligence for Postoperative Parameters Prediction in Implantable Collamer Lens Surgery'. Together they form a unique fingerprint.

Cite this